Compression Test Results

JVU – Process Pipe Part
Grain Direction: Horizontal Grain Direction: Vertical
material: DC01-C390/H material: DC01-C390/V
Ev/Sv modulus of elasticity: 35,000 kN/mm2 Ev/Sv modulus of elasticity: 35,000: 35,000 kN/mm2
1: 0,047 mm
2: 0,047 mm
1: 0,205 mm
2: 0,190 mm

The results will beĀ  apparent by inspection of the graphical results of the hysteresis:

  • The deformation of the JVU part is very low.
  • The deformation of the pipe part is shown very clearly.